China Medical Syringe Pump(SK-500II)&CE&ISO
1. Double CPU;
2. SK Syringe pumps has accurate pressure sensor detects occlusion pressure;
3. Excellent injection operation
Product Description
Function & Features:
* Awarded with ISO13485: 2003(TUV Germany) and CE Certification(CE0197)
* All standard syringes of 5ML 10ml, 20ml, 30ML 50ml(SK-500I)are compatible.
* The machine diagnoses the syringe size automaticallym and with a simple syringe specification setting, the Syringe pump can guarantee an accurate and safe injection.
* Unique function of bedside injection supervision which makes patients and their relatives as well as nurses more assured.
* Excellent injection function and operation. Even small-volume injection is accurate.
* Double CPU system ensures safe and reliable injection process.
* Driven by precision step motor, no pulsating waves shall occur during even low-rate injection.
* Accurate and sensitive pressure sensor detects occlusion pressure accurately.
* Alarms are given in case of malfunction or operation error and the machine stops operation automatically.
| Product type | SK-500II |
| Maximum injection rate | 1500ml/h (Different injectors have different maximum rate.) |
| Range of flow rate |
5ml injector: 0.1-100ml/h 10ml injector: 0.1-200ml/h 20ml injector: 0.1-400ml/h 30ml injector: 0.1-600ml/h 50ml injector: 0.1-1500ml/h |
| Injection increment | 0.1ml/h |
| Bolus rate |
5ml injector: 100ml/h 10ml injector: 200ml/h 20ml injector: 400ml/h 30ml injector: 400-600ml/h 50ml injector: 400-1500ml/h |
| Injection mode selection | 1. Rate mode 2. Time mode 3. Body Weight mode |
| Rate mode | Speed: 0.1-1500ml/h (maximum value depends on the injector specifications) |
| Time mode |
Time:1-2000 minutes Accumulated injection volume: 0.1-999.9ml |
| Body Weight mode |
Weight: 0.1-300.0kg Drug: 0.1-999.9(mg) Volume: 0.1-999.9ml Dose: 0.1-9999.9(restricted to unit, drug, solution, weight and injector specification). Unit: mg/kg/h, ug/kg/min |
| KVO rate | Adjustable range: 0.1ml/h-5.0ml/h (begin the KVO function under the occlusion situation) ; pressing STOP key to cancel the KVO function when it is unnecessary in use. |
| IP grade | IP21 |
| Injection pressure | The maximum pressure is 0.3Mpa, Occlusion alarm pressure value is 40kPa-160kPa when pressure value is minimum, injection rate is 25ml/h, the longest alarm time is 10 minutes. When pressure value is minimum, injection rate is 5ml/h, the longest alarm time is 10 minutes. |
| Preset volume | 0.1ml-9999.9ml |
| Preset time | 0-99 hours, 0-59 minutes |
| Accumulated injection volume | 0.1ml-9999.9ml |
| Accuracy | 3% |
| Power supply | AC 100-220V,50/60Hz |
| Battery | Rechargeable lithium polymer battery, 7.4 V, 1600mAh. |
| Maximum power consumption | 25VA, running more than 2 hours at the rate of 25ml/h after being fully charged. |
| Battery charge | When syringe pump is connected to AC power, the battery will automatically recharge. (about 8-14 hours to recharge fully.) |
| Fuses | T2AL250V- |
| Displayed information | Flow rate; accumulated injection volume; injector specification; battery capacity; bed No.; AC power indicator, operation indication, etc. |
| State indication information | Stop, inject, bolus, KVO (stop flashing, the other indicators flash by turns.) |
| Alarm information | near completion, Over, occlusion, low battery, abnormal 1 (communications failure), abnormal 2 (pump stuck), abnormal 3 (wrong parameter), volume limited alarm, no AC power |
| Maximum size of the outer shell | 288×130×122 mm(length×width×height) |
| Maximum weight | <3.0kg |
| Classification | ClassII, Type BF |
| Shell material | ABS plastic |
| Operating conditions | Environment temperature 5-40, air pressure 80kPa -106kPa,relative humidity ≤80% |
| Storage conditions | Environment temperature -40-55, air pressure 50kPa -106kPa,relative humidity ≤95% |
| Applicable syringes | 5ml.10 ml.20 ml.30ml.50 ml syringes |
| Electrical safety | In accordance with the stipulation of GB9706.1-1995 |
| Applied standards | According to the stipulation of YZB/Yue 001-2008 |